Новый товар
40 Товар Товары
Внимание: ограниченное количество товара в наличии!
Будет доступен:
Pro Q Switch Yag Laser Machine Tattoo Eyebrow Removal
Получатель: :
* Обязательные поля
или Отмена
ND: YAG Laser Cosmetic System introduces gem-adjusting Q switch, which uses high energy by instant emission of laser beam to crush and remove the pigment effectively in the pathologically changed tissues. That is an explosion led by laser beam: the laser beam at the fixed wavelength enabled by the accumulated high energy can reach the pathologically changed tissues through epidermis in a very short time (only 6 ns) to instantly crush the respective color base, then the corresponding pigment group gets swollen and outburst at last due to high energy, and part of the pigment group springs out of the human body (at shallow epidermis), and the rest (at basis tissues) pigment group will become very small particle before swallowed by the human cell which will be finally discharged out of the human body through lymphatic system circulation. The pigment of the pathological tissues will fade in color till it vanishes. And the surrounding normal tissues will not be ruined since they will not absorb the laser at that fixed wavelength .
The system gem-adjusting Q switch can effectively cure the mixed pigments by pigment precipitation of extraneous source with pathological pigment change of endogenous source, inclusive of erroneous dark eyebrow-embroidery, lip-embroidery, lip-soak, eye line-embroidery, lip-line, tattoo (inclusive of tattoo by extraneous wounds), pigment precipitation by sensitive source, freckle on female's face (male's), coffee spot, old age spot, black mole, and birthmark in black, blue, purple, brown, red and etc. Treatment course for different illness case as follows:
Treatments Treatment course required ( cure times) Treatment course interval Remark (requirements in surgery)
eyebrow-embroidery(eyeliner grain) 1 –2 times 30-60 days Eyebrow blow, eyeball protection
Eyebrow-embroidery ( eyeliner embroidery) 1-3 times 45-60 days Eyebrow blow, eyeball protection
Lip line (red dyed lip) 1-3 times 15-45 days Use 532nm filter
Tattoo(caused by extraneous wounds) 1-4 times 30-60 days Blood infiltration will be fine on wounds
Freckle, age spot 1-4 times 15-30 days Blood infiltration will be fine on wounds
Birthmark, nevus/mole 3-7 times 45-90 days Must have Blood infiltration .
1 Treatment for tattoo in eyebrow
Customer could not open eyes during treatment, operator should adjust energy according to depth of tattoo color, hold the handle and move it to treatment area slowly to make customer feel acceptable in mentally. Right now, the speed of flash could be set 3HZ, keep head of the handle a two-finger distance to treatment area, start treatment from head of eyebrow to end of eyebrow. It is needed to treat again in 5-10 minutes if the color of tattoo re-appear.
2 Remove eye line
The speed of flashes could be set 4-5HZ,adjust the energy of light to minimum energy, keep a one-finger distance between head of handle and treatment area. Operator should strictly protect customers’ eyes with panel for eyelid or medical pledget (panel for eyelid)of 1cm depth.
Treatment should be started from down eye line, customer should deeply close eyes and keep eyeball up-sight inside. Operator should press the pledget (panel for eyelid) with forefinger and push up eyelid, peel down eyelid with middle finger to bare the eye line, treat it with flashes of 4-5Hz. Then, treat up eye line. Also customer should close eyes and keep eyeball down-sight inside. Operator should press the pledget (panel for eyelid) with middle finger and push eyelid down, push eyelid up with forefinger to bare the eye line, treat it with flashes of 4-5Hz.
3 Remove lip line
The speed of flashes could be set 5Hz,keep a 3/4 finger distance between head of handle and treatment area. It is better to remove black, coffee, deep, red and brown lip line with 1064nm head at first time and then, treat again with 532 nm head.
Notice: All tattoos in lip should be treated in 6 months after making. OR removal treatment will fail. It should have 45-60 days interval to continue next treatment until remove all.
4 Remove tattoo
The speed of flashes could be set 3Hz/5Hz.It is better to use high energy for treatment until treatment area seeps a little blood. It should have 45-90 days interval to continue next treatment until remove all.
5 Remove spot and nevus
The speed of flashes could be set 3Hz/5Hz.Keep 3-4 fingers distance between head of handle and treatment area. It is better to use high energy for treatment until treatment area seeps a little blood. It is advised to use 1064 nm head for normal spot and nevus treatment, but for deep color spot and nevus, it is better to use 532nm head for treatment. It should have a 15-30days interval to continue next treatment until remove all.
6 Remove birthmark
The speed of flashes could be set 3Hz/5Hz.It is better to use high energy for treatment until treatment area seeps a little blood. It is advised to use 1064nm head for birthmark treatment, but for red and deep color birthmark, it is better to use 532nm head for treatment. It should have 45-90 days interval to continue
7.With black diamonds, freckle/wrinkle/whitening/shrink pores
Whitening theory:
Designed-wavelength laser acts on melanin on epidermis and deep dermis,"HEIWAWA" explodes surplus melanin on epidermis directly and crushes melanin in deep skin, Whitening could be finally achieved with those melanin being swallowed by phagocyte or expel from sweat gland directly
Pores astringing principle:spread nanometer-powdered-carbon on face
After it infiltrates into skin pores, laser is adopted to explode grain of powdered carbon,in which way, the epidermal dirts is shattered.The hyperyrexia energy produced is transmitted to dermis, fully stimulus the renewal and vigour of skin cells, enhancing restoration of collagen fibers and elastic fibers,Combined with the naturally restoration ability of skin,this device help new collagen deposit and rank in order.As a result, such result can be obtained as smooth cut and wrinkle removal,pores astringing,skin smoothing, elasticity regaining
Cooling condition: wind system+closed circulating+cooling system
Laser type: Q-switch Nd: YAG
Laser output wave length: 1064nm/532nm
The pulse energy: 0~1000mJ
Pulse width: 6ns
Recurrence rate: 1, 2, 3, 4, 5Hz
Power source: 110v~220v
1 × Main Unit
1x Handpiece
1 × 532nm tip (mainly used for red, coffee and brown pigment treatment)
1 × 1064nm tip (mainly used for blue, black and cyan pigment treatment)
1 × Water funnel
1 × Package box
4 × Key (two for the machine, two for the package box)
1 × Foot touch
1 × Protective goggle
1 × Power line (we stock 110V-240V power version and US.UK.UA.EU plugs for the country all of the world)
1.Innovative in laser technology,strict in technical detection,precise in manufacture,stable and effective in performance.
2.Special designed cooling system ensures constantly working.
3.Micro Computer counts the shoots.
4.Portable and aseismatic,convenient for transportation.
5.user friendly interface with LCD display
6.No injury to normal tissue.
7.Remove pigmentation without side effects or scar.
8.Short Treatment period with outstanding effect.
Пока нет обзоров.
$19,449.38
$2,417.55
$11,975.28
$3,382.80
$12,641.89
$2,864.06
$5,495.98
$2,443.75
$2,040.68
$3,387.00
$3,868.98
$668.00
$911.00
$975.00