Pro 2 Handle Fat Dissolve Cold Slimming Cooling Freezing Operationbeauty Machine

New product

40 Items

$5,309.08

Add to wishlist

More info

Pro 2 Handle Fat Dissolve Cold Slimming Cooling Freezing Operationbeauty Machine



INTRODUCTION

A number of methods have been attempted for Fat Dissolve including the use of led, ultrasound, radiofrequency electric current,since Cooling operation was developed appling cooling to tissue,was approved as the most effective way to fat reduction.This revolutionary new idea of dissolving fat, which is approved as an important technology progress in fat reduction since it is put into use.For those people who is on diet,do regular exercise but still remove local fat,Cool Freeze definitely a great gift. For fat intensive parts and less parts, such as love handles (flanks), and back fat. (loose fat above the hip on both sides of waist), belly and back fat, Cool Freeze produce stunning results .



TECHNOLOGY BACKGROUND

Too much fat can damage people's appearance and athletic ability. May also cause various. Too much fatty tissue can be located in various parts of the body, including the thigh, buttocks, abdomen, knee, back, face, arms and other areas. And an excess of adipose tissue may be cause ugly appearance formed by cellular. Excess body fat also related to significant health risk. So we need effective method to control or eliminate excess body fat.it is a cosmetic surgery procedure that slims and reshapes specific areas of the body by removing extra fat deposits. Usually operated by the Plastic Surgery or dermatologist with a special surgical instruments for it, it is an invasive way to remove subcutaneous fat tissue.
There are also possible fatal complications and negative side effects associated with having it. These temporary factors include swelling, painful bruising, pain, numbness, limited mobility and allergic reaction.In addition, it is of high cost. There are other new emerging technologies to remove subcutaneous adipose tissue, including Mesotherapy led-assisted it and high-intensity focused ultrasound..
Other non-invasive way to remove excessive fat including drugs, diet pills, regular exercise, diet control, or a combination of these methods.A disadvantage of these treatments is likely invalid, and even in some cases impossible. For example, when a person physically injured or sick, you can not select the way of regular exercise. Similarly, when the diet pills or external use of drugs are allergic or cause adverse reactions, in addition, the use of physical or systemic approach to lose weight, you can not eliminate the body fat of a selected area.
The Cooling procedure is fundamentally different from other non- or minimallyinvasive modalities, and it was approved as the most effective way to fat reduction. This revolutionary new nat loss method, which is approved as an important technology progress in fat reduction since it is put into use.For those people who is on diet, do regular exercise but still remove local fat, Cool Freeze definitely a great gift. For fat intensive parts and less parts, such as love handles (flanks), and back fat. (loose fat above the hip on both sides of waist), belly and back fat, Cool Freeze can produce stunning results .



PROCESS

1.Test the heart rate of the people who is receiving the treatment, whether it is normal[50-100],
2.Check the thickness of the fat
3.Clean operation area ,Clear the hair of the operation area
4.Mark the size of operation area
5.Use antifreeze on the operation area
6.Paste antifreeze membrane at operation part.
7. Patients receiving the operation should be sitting Make upper body and lower limbs to 90 degrees.
8.Choose the program according to thickness of fat.[P1, P2, E]
9.Start the machine. [start button]
10.Make the cooling device to suck the operation area gently, press the control button in the handle once, and set the vacuum suction intensity.
11.When the suction strength is suitable, press the control button in the handle again, to keep the constant suction. Adjust the suction appropriately to make it acceptable for the user.
12.Timing of treatment
13.25-30 minutes after treatment, press the control button in the handle, to stop the suction.And check and add antifreeze.
14.Repeat steps 10 to 11 until the operation course finished[press the start button the again] and turn off the power.



CAUTION

1.The equipment must be operated by professionals
2.Do not use without antifreeze
1.The equipment must be used by professionals
2.Patients using the following medical electrical equipment can not use the equipment.
Implanted cardiac pacemakers or other implanted electronic devices;
Life-sustaining artificial heart-lung machines and other equipment;
Portable ECG measurement equipment;
3.The following patients should be agreed by the professional doctors before using the equipment.
Patients with acute ;
Malignancy
Patients with Infectious
Pregnant women;
Patients with heart
Patients with fever
Patients are receiving operation or those with abnormal body phenomenon;
4.The following patients using this device should be taken care of.
Infants and young children;
Sensory or physically impaired persons;



PARAMETERS

1.Voltage 220V/50Hz or 110V/50Hz according to the mark on the machine
2.Power:<800VA
3.Cold: 5? -10?
4.Heat:37?-45?
5 Light :Red(630nm) Green(570nm) 50mwx4
6.Vacuum:10-80Kpa
7.Cooling liquid:pure water or special coolant
8.Fuse:T3.15AL250V
9.Ambient temperature:5 degree-40degree
10.Relative humidity:<=80%
11.Atmospheric pressure:80Kpa-106Kpa



ACCESSORIES LIST

1 x Power supply line
2 x Handle support
1 x User manual
1 x Cooling liquid tank
2x Cooling handles
1 x Emergency switch

Reviews

No customer reviews for the moment.

Write a review

 Pro 2 Handle Fat Dissolve Cold Slimming Cooling Freezing Operationbeauty Machine

Pro 2 Handle Fat Dissolve Cold Slimming Cooling Freezing Operationbeauty Machine

30 other products in the same category: