6in1 Cavitation Ultrasonic Vacuum Rf Tripolar Multipolar Bipolar Bio Slimming

New product

40 articles

$1,795.00

Add to wishlist

Daha ətraflı

6in1 Cavitation Ultrasonic Vacuum Rf Tripolar Multipolar Bipolar Bio Slimming

WORKING PRINCIPAL:

Wave fat system,
With collective strong sound wave head, strong sound wave of 40KHZ may be emitted to vibrate fat cells at top speed and product numerous vacuum air pockets inside and outside the fat cells, robustly impact fat cells to generate introverted blast and disintegrate triglyceride into glycerol and free fatty acids. Then RF waves at frequency of 1M HZ is used for exhausting the integrated glycerol and free fatty acids through hepatoenteral circulation.. Finally, vacuum RF and energy electrode are used for positioning and tightening fat. In physics, it is know as cavitation. Micropore introverted blast inside and outside cell may lead to enhanced molecular motion and a higher energy level and this will finally cause fat cell rupture and thereby achieve the effects of body building and losing weight.

40KHZ ULTRASONIC

40Khz ultrasonic handle
Strong sound wave explosion fat head
With collective strong sound wave head, strong sound wave of 40KHZ may be emitted to human body for impacting fat cells fiercely and causing friction motion between fat cells. This may cause effective comsumption of calories and moisture in fat cells and reduce the size of fat cells. What’s more, sound wave vibration may cause fierce impact of fat cells to make them be exploded instantaneously, reduce the amount of fat cells and thereby achieve the effects of removing fat.

2.Vacuum bipolar RF handle
Dissolve fat, lymphatic drainage, firm skin and enhance skin elasticity
Body-shaping equipment adopts the most advanced high-speed turbine negative technology, and innovative three-dimensional conversion technology, combining with microcomputer chip controlled patent roller axis, and has an anti-geocentric attract effect on the skin.
Attracting and outspreading the fibrillar connective tissue of different cortexes, through the rhythmic massage and effectively break down subcutaneous fat and reduce cellular tissue accumulation of fat, use of the patents to massage deeply roller different parts of the body, bring up fat layer in dermis, curium and subcutaneous, and release micro-vascular lymphatic vessels at the same time, promoting metabolism and to make fat cells in a passive movement of fat acids, even within the cells of toxins, also to be eliminated from lymphatic system in vitro, the detoxitication enhance the function of as many as four times. Can be done manually or any other instruments can not achieve the perfect results. At the same time, skin is more elastic and luster. It is the “healthy body sculpture management” expert.


RF RADIO FREQUENCY

Being integrated with the most advanced RF technology and radio frequency, the instrument may directly reach the deep-seated fat body and havethe excellence of targeted positioning RF. In the fast-active sate, fat cell tissue may generate fiction heat, increase local temperature and remove excess fat and toxin from the body through sweat gland, enterohepatic circulation and lymph and ultimately achieve the effect of dissolving fat. With controlled depth technology, inlaid diamond particles of different sizes may rub skin alongits pattern, adjust suction strength by means of vacuum draw and rub with negative strongforce to directly explode thick fat,. Thus, the effects are very odvious: Enhance blood circulation, accelerate effectively improve the state of areolar tissue, remove stubborn fat and improve the sufficient adsorption condition of diet products.



Function:
facial wrinkle elimination, tightening and lifting
A capacitive coupling electrode is used for transmitting radio-wave energy and generating an electric field for entering into subcutaneous tissue through the skin surface. In the high-frequency of 450khz, this electric filed changes its polarity for 450,000 times per second. To reply to the rapid change in electrode, directions of electrical particles the skin are also changed. By this time, natural electric resistance in the subcutaneous tissues moves and generates heat energy. As the papillary dermis collagen may immediately shrink when the temperature is within the range from 60 to 70 celcius degree, after wrinkle treatment, client may immediately sense the skin tightening effects as it is being lifted and firmed. When collagen is produced continuously, thickness and density of the skin papillary dermis may be increased to remove wrinkles, eliminate scars, restore skin elasticity and gloss and make it be blonde and smooth. While collagen is increased, fresh skin is generated in the position of operation and wrinkles are removed by large amount of cells. In addition, when cortex without elasticity or that with thick horny layer in the area with wrinkles is separated, surrounding skin will also be renewed.



Caution for using RF
1.beautician should wear insulated gloves during operation
2.do not wear any aglet, both for the beautician and the users
3. the electrode probe must be fully in contact with skin
4.do not make the RF electrode stay on any part without moving. Keep it moving on skin slowly.
5.skin around eyes and forehead is very thin, the RF output intensity should be relatively weakened.
6.do not contact skin with unipolar when using of bipolar, tripolar, hexpolar RF work head otherwise it will produce pulse discharge, gel paste etc. Products like gel maybe evaporated into a mist..

BIO

Skin tightening after cellulite and fat breaking down:
Lifting up, for example, faces, breasts,hips and etc.
BIO operating instruction:
Operating instruction
1.connect one pair handle to BIO outlet.
There are 3 pairs different handles available:
Mushroom handles: for large area such as the cheeks, forehead, neck, etc
Spot handles: for small area, such as nasal fossa, and so on.
Handles without cap: please insert the cotton stick (which you can find them in the manual book plastic bag), then dampen the cotton with anti-wrinkle essence of other kind of essences. Its operating method is same as the other 2 kinds of handles.
Note: handle with damp cotton stick conducts electricity stronger than the other 2 kinds of handles.
3.. select the time as you like about 15 minutes of 30 minutes.
4. select the strong or weak intensity.
5. select the mode just you like such as hip, bust, neck or face.
Can be used on:
Micro wave anti-wrinkle massage suitable for sagging, ageing, excrescence skin and eye bag muscle..
Skin maintain the pores and vessels, clean up pores and vessels.

USING GUIDANCE

1.operation schematic drawing of 40K cavitation explode work head
2.operation schematic drawing of sextuple RF led work head for body
waist and abdomen care (25 minutes, 2-3 days/time)
a.massage to navel as center and gradually expanding the range
b.massage chest nest, both sides of former abdomen and below the navel (into diamond) from inside to outside in circles.
c.Concentrated the fat from 4 directions to navel as center
d.Massage from end of pelvis to groin in circles.
e.Massage from inner rib to outer edge in circles.
f.Massage back and forth from inner rib to outer edge in straight line
g.Liftihip andhe lower part of the body care (30 minutes, 2-3 dats/time) used the D50mn probe 
Concentrated the fat to groin in circles of straight line,ng from inner rib to outer edge after massage.
3.operation schematic of tripolar RF work head for face
a.massage the mandible center in circles to produce deep heat.
b.Massage lower jaw in lines.
c.Massage the triangle zone of both sides of the face in circles.
d.Massage from jaw to angulus oris to ear in lines

ADVERTION& NOTICE

Advertion
1.pregnant women or women during in menses
2.epileptic
3.patients with malignancy
4.patient whose wound after operation has not healed up
5.acute inflammation of epidemical patients
6.whom with heart diseases or with heart pacemaker
7.whom with kidney (gall-stone) disease.
8.who was embedded metal object or silica gel
9.who in menses, birth control period, emiction incontinence period, or accepting the belly operation
10.whose body always take much inner hot
11.who has the genetic hypersensitivity


Notice
1.be sure to use the special ultrasonic gel
2.avoid knocking the us head
3.for avoiding burning the head, during operation, please prepare enough ultrasonic gel.
4.don’t stay in one place, avoid treating on he bone
5.don’t use disinfectant product to disinfect the us head. We suggest the wet cotton or dry towel enough,.
6.check the machine power cord if it is connected well,
7.if the machine will not use for l long time, please switch off it, and power off
8.please take off all metal decoration from the operator and patient’s body
9.if continuous using 1 hour, please pause the machine about 10 minutes, then using again.
10.during the operation, be sure not to accept other treatment.

Reviews

No customer reviews for the moment.

Write a review

6in1 Cavitation Ultrasonic Vacuum Rf Tripolar Multipolar Bipolar Bio Slimming

6in1 Cavitation Ultrasonic Vacuum Rf Tripolar Multipolar Bipolar Bio Slimming

30 other products in the same category: